Home
Water Testing Products
IDEXX Tecta
Coliforms
Enterococci
Legionella Pneumophila
Pseudomonas Aeruginosa
Heterotropic Plate Count
Colilert
Colilert-18
Colisure
Legiolert
Pseudalert
Enterolert-DW
EasyDisc
EasyDisc YEA Test
EasyDisc PCA Test
EasyDisc PCA Test
EasyDisc Platform
Home
Water Testing Products
IDEXX Tecta
Coliforms
Enterococci
Legionella Pneumophila
Pseudomonas Aeruginosa
Heterotropic Plate Count
Colilert
Colilert-18
Colisure
Legiolert
Pseudalert
Enterolert-DW
EasyDisc
EasyDisc YEA Test
EasyDisc PCA Test
EasyDisc PCA Test
EasyDisc Platform
More
  • Home
  • Water Testing Products
  • IDEXX Tecta
  • Coliforms
  • Enterococci
  • Legionella Pneumophila
  • Pseudomonas Aeruginosa
  • Heterotropic Plate Count
  • Colilert
  • Colilert-18
  • Colisure
  • Legiolert
  • Pseudalert
  • Enterolert-DW
  • EasyDisc
  • EasyDisc YEA Test
  • EasyDisc PCA Test
  • EasyDisc PCA Test
  • EasyDisc Platform
  • Home
  • Water Testing Products
  • IDEXX Tecta
  • Coliforms
  • Enterococci
  • Legionella Pneumophila
  • Pseudomonas Aeruginosa
  • Heterotropic Plate Count
  • Colilert
  • Colilert-18
  • Colisure
  • Legiolert
  • Pseudalert
  • Enterolert-DW
  • EasyDisc
  • EasyDisc YEA Test
  • EasyDisc PCA Test
  • EasyDisc PCA Test
  • EasyDisc Platform

Colisure

Detect coliforms/E. coli with the convenience of a long-read window

Simultaneously detects both total coliforms and Escherichia coli; positive results have a distinct magenta color. Results valid through 48 hours.

  • Distinct magenta color means there's no mistaking a positive result.
  • The Colisure Test also suppresses high levels of noncoliforms, including Aeromonas.
  • The Colisure Test is U.S. EPA approved and included in Standard Methods for Examination of Water and Wastewater.

Overview

Easy

Economical

Rapid

  •  Distinct magenta color is easy to see.
  • Ease of use simplifies training.
  • Unit-dosed packaging eliminates media preparation.
  • Quality Control (QC) procedure can be done in 15 minutes.

Rapid

Economical

Rapid

  • Less than 1 minute of hands-on time.
  • Detects coliforms and E. coli simultaneously in 24 hours or less.
  • No confirmations needed.
  • No glassware cleaning or colony counting.

Economical

Economical

Economical

  • Minimises evening and weekend work.
  • Up to 12-month shelf life at room temperature.

Accurate

Accurate

Economical

  •  Definitive results at 24 hours; can be read up to 48 hours.
  • Identifies E. coli specifically, eliminating unneeded public notification due to non-target organisms.
  • Suppresses up to 2 million heterotrophs per 100 mL.
  • Eliminates the subjective interpretation found in traditional methods.
  • Detects a single viable coliform or E. coli per sample.

Flexible

Accurate

Flexible

  •  The Colisure Test can be used for presence/absence (P/A) or quantification testing.
  • Quanti-Tray provides counts to 200/100 mL without dilutions.
  • Quanti-Tray/2000 provides counts to 2,419/100 mL without dilutions.

The Science

How the Colisure Test works

The Colisure Test uses proprietary Defined Substrate Technology (DST) nutrient indicators CPRG and MUG to detect total coliforms and E. coli. Coliforms use the β-galactosidase enzyme to metabolize CPRG and change it from yellow to magenta. E. coli use β-glucuronidase to metabolize MUG and create fluorescence.

 

How To Use

Learn how to use the Colisure test

Presence/Absence

Step 1

 Add reagent to sample and incubate at 35 ± 0.5°C for 24 hours. 

Step 2

 Read results:

  • Yellow = negative
  • Magenta = total coliforms
  • Magenta/fluorescent = E. coli

Quantification

Step 1

Step 1

Step 1

 Add reagent to sample. 

Step 2

Step 1

Step 1

 Pour into Quanti-Tray (counts from 1–200) or Quanti-Tray/2000 (counts from 1–2,419). 

Step 3

Step 1

Step 4 - Quanti-Tray

 Seal in Quanti-Tray Sealer and place in incubator at 35 ± 0.5°C for 24 hours. 

Step 4 - Quanti-Tray

Step 4 - Quanti-Tray/2000

Step 4 - Quanti-Tray

Quanti-Tray—Read results:

  • Magenta wells = total coliforms
  • Magenta/fluorescent wells = E. coli
  • Count positive wells and refer to MPN table

Step 4 - Quanti-Tray/2000

Step 4 - Quanti-Tray/2000

Step 4 - Quanti-Tray/2000

 Quanti-Tray/2000—Read results:

  • Magenta wells = total coliforms
  • Magenta/fluorescent wells = E. coli
  • Count positive wells and refer to MPN table

Frequently Asked Questions

Please reach us at vega@aguasegura-ao.com if you cannot find an answer to your question.

Yes, the Colisure Test is U.S. Environmental Protection Agency (EPA) approved as a method for total coliforms and E. coli detection in drinking water and for E. coli detection in groundwater. 


The Colisure Test detects coliforms and E. coli at 1 organism/100 mL. 


 The shelf life for the Colisure Test is up to 12 months from date of manufacture. 


  Store at 2–25°C and away from light. 


There is no comparator for the Colisure Test. For comparison, use a negative control when interpreting results. 


The reagent system was designed to suppress non-coliform CPRG or MUG positive bacteria for at least 48 hours. If incubation extends past 48 hours, it is possible that such bacteria could overcome the reagent and react with CPRG or MUG. When incubation exceeds 48 hours, only negative results are valid. Positive results must be confirmed. 


Check with your local, state, and/or federal authorities for proper disposal of bacteriological biohazard materials at your facility. 


If an inoculated Colisure Test sample is inadvertently incubated over 48 hours, lack of red to magenta color is a valid negative test; a red to magenta color after 48 hours is not valid and should be repeated. 


An inoculated Colisure Test sample that is positive for coliforms and E. coli before 24 hours is a valid positive test for both coliforms and E. coli. If the sample is positive before 24 hours for coliforms only, the sample is a valid positive test for total coliforms. However, the sample should be incubated for a longer period (at least 24 hours, but not greater than 48 hours total time) to determine whether E. coli are present. 


Yes, when using the Colisure Test with Quanti-Tray, Quanti-Tray/2000 or any multiple-tube format, be sure to use IDEXX Antifoam Solution or a vessel with antifoam. 


The Colisure reagent powder should be tan in color; it should be dry and free-flowing. Any concerns about the color or integrity of the powder should be directed to IDEXX Technical Support. 