Home
Water Testing Products
IDEXX Tecta
Coliforms
Enterococci
Legionella Pneumophila
Pseudomonas Aeruginosa
Heterotropic Plate Count
Colilert
Colilert-18
Colisure
Legiolert
Pseudalert
Enterolert-DW
EasyDisc
EasyDisc YEA Test
EasyDisc PCA Test
EasyDisc PCA Test
EasyDisc Platform
Home
Water Testing Products
IDEXX Tecta
Coliforms
Enterococci
Legionella Pneumophila
Pseudomonas Aeruginosa
Heterotropic Plate Count
Colilert
Colilert-18
Colisure
Legiolert
Pseudalert
Enterolert-DW
EasyDisc
EasyDisc YEA Test
EasyDisc PCA Test
EasyDisc PCA Test
EasyDisc Platform
More
  • Home
  • Water Testing Products
  • IDEXX Tecta
  • Coliforms
  • Enterococci
  • Legionella Pneumophila
  • Pseudomonas Aeruginosa
  • Heterotropic Plate Count
  • Colilert
  • Colilert-18
  • Colisure
  • Legiolert
  • Pseudalert
  • Enterolert-DW
  • EasyDisc
  • EasyDisc YEA Test
  • EasyDisc PCA Test
  • EasyDisc PCA Test
  • EasyDisc Platform
  • Home
  • Water Testing Products
  • IDEXX Tecta
  • Coliforms
  • Enterococci
  • Legionella Pneumophila
  • Pseudomonas Aeruginosa
  • Heterotropic Plate Count
  • Colilert
  • Colilert-18
  • Colisure
  • Legiolert
  • Pseudalert
  • Enterolert-DW
  • EasyDisc
  • EasyDisc YEA Test
  • EasyDisc PCA Test
  • EasyDisc PCA Test
  • EasyDisc Platform

Pseudalert

24-hour detection of Pseudomonas aeruginosa

  • Detects P. aeruginosa in 24 hours with no additional confirmation steps. 
  • The ISO international standard for 24-hour detection of P. aeruginosa in water - ISO: 16266-2:2018. 
  • Method 9213G in Standard Methods for Examination of Water and Wastewater. 
  • Minimizes the risk of false positives from nontarget organisms.
  • Same easy-to-use platform as the Colilert Test.
  • Safeguard against "hot-tub rash," "swimmer’s ear," and a host of other infections, avoiding illness in sensitive populations.

Overview

Easy

Accurate

Rapid

 Blue fluorescence of wells or vessel indicates a positive result.

  • Same familiar platform as the Colilert Test: 
    • Ready-to-use reagents, no media preparation.
    • Convenient unit-dosed packaging.
    • No toxic compounds.
  • Use with Quanti-Tray or Quanti-Tray/2000 for most probable number (MPN) enumeration.

Rapid

Accurate

Rapid

  • Definitive results in 24 hours.
  • Less than 1 minute of hands-on time for streamlined testing work flow.

Accurate

Accurate

Accurate

  • Specifically detects Pseudomonas aeruginosa, reducing the risk of false positives from nontarget organisms.
  • Results are definitive without additional confirmation steps.
  • Simple blue fluorescent change minimizes subjective result interpretation.

The Science

How the Pseudalert Test works

    The Pseudalert Test detects the presence of Pseudomonas aeruginosa in water samples.


The test is based on a bacterial enzyme detection technology that signals the presence of P. aeruginosa through the hydrolysis of a substrate in the Pseudalert reagent. P. aeruginosa cells rapidly grow and reproduce using the rich supply of amino acids, vitamins, and other nutrients present in the Pseudalert reagent. Actively growing strains of P. aeruginosa have an enzyme that cleaves the substrate in the reagent to produce blue fluorescence under ultraviolet light.


 Pseudalert detects Pseudomonas aeruginosa at 1 cfu per 100 mL water sample within 24 hours. 

How To Use

Learn how to use the Pseudalert test

 

Presence/Absence (P/A)

Step 1

Step 1

Step 1

 Add reagent to sample (sample will turn yellow), and then incubate at 38°C±0.5°C for 24–28 hours. 

Step 2

Step 1

Step 1

 Read under ultraviolet (UV) light. Blue fluorescence indicates presence of P. aeruginosa. See the Pseudalert Quick Reference Guide (PDF) for tips on reading fluorescence. 

Quantification

Step 1

Step 1

Step 1

  Add reagent to sample (sample will turn yellow). 

Step 2

Step 1

Step 1

 Add IDEXX Antifoam Solution to vessel. 

Step 3

Step 1

Step 3

 Pour sample into Quanti-Tray (counts from 1–200) or Quanti-Tray/2000 (counts from 1–2,419). 

Step 4

Step 4

Step 3

 Seal using a Quanti-Tray Sealer, and then incubate at 38°C ± 0.5°C for 24–28 hours. 

Step 5

Step 4

Step 5

 Read under ultraviolet (UV) light. Blue fluorescence indicates the presence ofP. aeruginosa. Count the positive (blue fluorescent) wells and refer to MPN table. See the Pseudalert Quick Reference Guide (PDF) for tips on reading fluorescence. 

Copyright © 2023 Agua Segura Angola - All Rights Reserved.

  • Privacy Policy

Phone Vega on +244 949 971 592

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

DeclineAccept